+86-15335001258

6F22 9V Industrial Carbon Battery

Home / Product / Carbon Battery / Industrial Outfit / 6F22 9V Industrial Carbon Battery

6F22 9V Industrial Carbon Battery

The 6F22 9V Industrial Carbon Battery is a dependable and durable energy source for a huge variety of commercial programs. Designed with splendid carbon substances, this battery offers long-lasting and constant energy output. Its compact shape and length make it easy to put in in devices and gadget. The 6F22 9V Industrial Carbon Battery is famend for its super performance and reliability, making sure uninterrupted operation in various disturbing environments. Whether it is for alarms, wi-fi communication gadgets, or electronic gadgets, this battery presents the important energy to maintain operations running easily.
+86-15335001258 / +86-15601503798 [email protected]
  • Parameter
  • Detailed Description
  • Get A Free Quote

Model:

6F22

Standard:

9V

Product Size:

26.5(D)*48.5(H)mm

Weight:

36.5g

Package:

Shrink/hang card

Certification:

CE, ROHS, SGS, REACH, UL, KC, UN38.3, MSDS

1. Scope
This specification governs the technical requirements of the Daily-max Carbon Zinc battery of 6F22. If it doesn’t list the other detailed requirements, the technical requirements and dimensions of the battery should meet or above GB/T8897.1-2008 and GB /T8897.2-2013.
1.1Reference Document
GB/T8897.1 (IEC60086-1,MOD)(Primary Battery Part 1: General)
GB/T8897.2 (IEC60086-2,MOD)(Primary Battery Part 2: Dimensions and Technical Requirements)
GB8897.5 (IEC 60086-5,MOD)(Primary Battery Part 5: aqueous electrolyte battery safety requirements)
1.2Environmental protection standard
The battery accord with 2006/66/EC

2. Chemical system, Voltage and Designation
Electrochemical system: zinc - manganese dioxide (ammonium chloride electrolyte  solution), does not contain mercury
Nominal voltage:1.5V
Naming : IEC:6F22    JIS: 006P    

3. Battery Size
Conform to the requirements of the brief
 
3.1 Acceptance tool
Using an vernier caliper measurement precision is not less than 0.02 mm, measure to prevent the battery short circuit, one end of the caliper head card should be labeled as a layer of insulating materials。
3.2 Acceptance methods
The GB2828.1-2003 normal inspection sampling plan at a time, special inspection level S-3, acceptance quality limit AQL=1.0

4. Weight and discharging capacity
Typical Weight: 36g
discharge capacity:150mAh(load 180Ω, 24h/day, 20±2℃,RH60±15%, final 
voltage 4.8V)
 
5. open-circuit voltage、closed - circuit voltage and short-circuit current

items

OCV(V)

sampling standard

After 2 months, a new battery

10.0~10.3

GB2828.1-2003 Normal inspection sampling plan, special inspection level S-4, AQL=1.0

After 12 months at
room temperature

9.8~10.0

Test conditions

load resistance 3.9Ω, measuring time 0.3 seconds, temperature 20±2℃


6. Discharging Ability

temperature:20±2℃

Discharge Conditions

GB/T8897.2-2008
National standard requirement

Shortest Average
Discharging Time

Discharge load

Discharge Time

Cut-off discharge voltage

 

After 2 months, a new battery

After 12 months at
room temperature

620Ω

2h/d

5.4 V

26h

26h

23.4h

270Ω

1h/d

5.4 V

8h

8h

7.2h

180Ω

24h/d

4.8 V

/

3.5h

3.1h

Satisfaction Standard:
1)9 pieces of battery will be tested for each discharging standard;
2)The result of the average discharging time from each discharging standard shall be equal to or more than the average time requirement; no more than one battery has a service output less than 80% of the specified requirement. Then the batch battery performance test qualified.
3)If nine sections of the battery discharge average is less than the specified value of average discharge time and (or) is less than the specified value of 80% of the battery number more than 1, we should take another 9 batteries to test again and calculate the average. Calculation results conform to the requirement of Article 2, the batch battery performance test qualified. If it does not conform to the requirement of article 2, the batch battery performance test is unqualified, and no longer tested.
 
7. Anti-leakage ability

Discharge Conditions

requirement

Acceptance Standard

Environmental
conditions

Discharge load
(Ω)

Discharge Time

Cut-off discharge voltage(V)

at temperature 20±2℃; relative humidity: 60±15% RH

620

2h/d

3.6

 No leakage was recognized by the eyes

N=9
Ac=0
Re=1

270

1h/d

180

24h/d


8. Safety Characteristics

items

Condition

Requirement

Acceptance Standard

External short circuit

At temperature 20±2℃, With wires to the battery positive negative switched on 24 hours

No explosion
allowed

N=5
Ac=0
Re=1


9. Signs
The following markings will be printed, stamped, or impressed on the body of the battery:
1. Designation: 6F22
2. Manufacturer or trademark: Daily-max
3. Polarity:“+”and“-”
4. Expiration date deadline or manufacturing time
5. The attention notes for safe use.

10. Cautions for Use
1. Since the battery is not manufactured for recharging, there are risks of electrolyte leakage or causing damage to the device if the battery is charged.
2. The battery shall be installed with its “+” and “-” polarity in the correct position, otherwise may cause a short circuit.
3. Short-circuiting, heating, disposing of into fire, or disassembling of battery is prohibited.
4. The battery can not be forced to discharge, which s to excess gassing and may result in bulging, leakage, and de-crimping of the cap.
5. New batteries and used ones can not be used at the same time. It is recommended to use the same brand when replacing batteries.
6. Electrical appliances should be taken out the battery when not in use for a long time
7. Exhausted batteries shall be removed from the compartment to prevent over-discharge.
8. Prohibit direct welding battery, otherwise, it will damage the battery.
9. Battery is to be kept away from children. If swallowed, contact a physician at once.
 
11. Normal Packing
Every 2 or 3 and 4 batteries or according to customer requirements with 
transparent membrane after hot shrinkage, each 60 knots in 1 inner box, 
20 boxes into 1 box.

12. Storage and shelf life
1. Batteries should be stored in a ventilated, cool, and dry place。
2. The battery should not be exposed to direct sunlight for a long time or in the rain。
3. Not to mix the removed packaging battery stack
4.Stored at condition of tempreture20℃±2℃, relative humidity 60±15%RH, the battery shelf life is 2 years。

13. Typical discharge curve
Discharge environment:20℃±2℃,RH60±15%
With parameter adjustment, product technology updates, and technology specifications will update at any time, please do not hesitate to contact us to stand for the latest version of the specification.

Get Free Quotes


About Us

Changzhou Strengh (Anyida) Power Technology Co., Ltd. is a private enterprise in Jiangsu specializing in the research, development, production and operation of primary batteries. The company's advanced production equipment, sophisticated testing equipment, and standardized management provide a reliable guarantee for the stability and improvement of product quality. A large amount of capital has been invested in new product development and technological innovation, and a large number of high-tech talents have been introduced. At present, engineering and technical personnel have accounted for more than 25% of the total number of employees, with strong economic and technical strength. The company has passed ISO9001, ISO14001, UL, CE, ROHS, SGS, REACH and other certifications and tests.

News

Contact us now