The Industrial R6P Silver Blue-2S Battery is a robust and reliable energy supply designed in particular for commercial applications. With its robust production and performance, this battery is an outstanding preference for heavy-responsibility gadgets and system. Whether it is powering industrial equipment, equipment, or security systems, the Industrial R6P Silver Blue-2S Battery affords steady and lengthy-lasting strength. Its compact size ensures easy installation and compatibility with a huge variety of business gadgets. Count at the Industrial R6P Silver Blue-2S Battery to supply reliable and green performance in disturbing work environments.
+86-15335001258 / +86-15601503798 [email protected]
  • Parameter
  • Detailed Description
  • Get A Free Quote

Model:

R6P

Standard:

1.5V

Product Size:

10.5(D)*44.5(H)mm

Weight:

7.2g

Package:

Shrink/hang card

Certification:

CE, ROHS, SGS, REACH, UL, KC, UN38.3, MSDS

1. Scope
This specification governs the technical requirements of the Daily-max Carbon Zinc battery of R6P/AA. If it doesn’t list the other detailed requirements, the technical requirements and dimensions of the battery should meet or above GB/T8897.1 and GB /T8897.2.
1.1Reference Standards
GB/T8897.1 (IEC60086-1,MOD)(Primary Battery Part 1:General)
GB/T8897.2 (IEC60086-2,MOD)(Primary Battery Part2:Size and Technical requirements)
GB8897.5 (IEC 60086-5,IDT)(Primary Battery Part5:Safety of batteries with aqueous electrolyte)
1.2Environmental Protection Standard
The battery meets the standard of EU battery directives 2006/66/EC.

2. Chemical system, Voltage and Designation
Electrochemical system: zinc - manganese dioxide (ammonium chloride electrolyte  solution), does not contain mercury
Nominal voltage:1.5V
Naming :IEC: R6P     ANSI: AA     JIS:SUM-3     Others: 15F

3. Battery Size
Conform to the requirements of the brief
3.1 Acceptance tool
Using an vernier caliper measurement precision is not less than 0.02 mm, measure to prevent the battery short circuit, one end of the caliper head card should be labeled as a layer of insulating materials。
3.2 Acceptance methods
The GB2828.1-2003 normal inspection sampling plan at a time, special inspection level S-3, acceptance quality limit AQL=1.0

4. Weight and discharging capacity
Typical Weight: 14.0g
discharge capacity:800mAh(load 43Ω,4h/day,20±2℃,RH60±15%, final 
voltage 0.9V)

5. open-circuit voltage、closed - circuit voltage and short-circuit current

items

OCV(V)

CCV(V)

SCC(A)

sampling standard

After 2 months, a new battery

1.62

1.40

4.0

GB2828.1-2003 Normal inspection sampling plan, special inspection level S-4, AQL=1.0

After 12 months at
room temperature

1.58

1.30

3.00

Test conditions

load resistance 3.9Ω, measuring time 0.3 seconds, temperature 20±2℃


6. Discharging Ability

temperature:20±2℃

Discharge Conditions

GB/T8897.2
National standard requirement

Shortest Average
Discharging Time

Discharge load

Discharge Time

Cut-off discharge voltage

 

2 months, new battery

After 12 months at
room temperature

10Ω

1h/d

0.9 V

4.1h

6h

5.4h

43Ω

4h/d

0.9 V

27h

29h

27h

1.8Ω

15s/m,24h/d

0.9 V

75 cycles

150 cycles

135 cycles

24Ω

15s/m,8h/d

1.0 V

11h

15h

13.5h

3.9Ω

1h/d

0.8 V

65min

130min

115min

3.9Ω

24h/d

0.8 V

/

95min

85min

Satisfaction Standard:
1)9 pieces of battery will be tested for each discharging standard;
2)The result of the average discharging time from each discharging standard shall be equal to or more than the average time requirement; no more than one battery has a service output less than 80% of the specified requirement. Then the batch battery performance test qualified.
3)If nine sections of the battery discharge average is less than the specified value of average discharge time and (or) is less than the specified value of 80% of the battery number more than 1, we should take another 9 batteries to test again and calculate the average. Calculation results conform to the requirement of Article 2, the batch battery performance test qualified. If it does not conform to the requirement of article 2, the batch battery performance test is unqualified, and no longer test.
 
7. Anti-leakage ability

items

Conditions

requirement

Acceptance Standard

Over-discharge

at temperature 20±2℃; relative humidity: 60±15% RH ,
load 10Ω ,
Discharge one hour every day until the voltage turns to 0.6V

 No leakage was recognized by the eyes

N=9
Ac=0
Re=1

High-temperature storage

Stored at 45±2℃, Under the environment of relative humidity to 90% RH for 20 days

 

N=30
Ac=1
Re=2


8. Safety Characteristics

items

Condition

Requirement

Acceptance Standard

External short circuit

At temperature 20±2℃, With wires to the battery positive negative switched on 24 hours

No explosion
allowed

N=5
Ac=0
Re=1


9. Signs
The following markings will be printed, stamped, or impressed on the body of the battery:
1. Designation: R6P/ AA
2. Manufacturer or trademark: Daily-max
3.Polarity:“+”and“-”
4. Expiration date deadline or manufacturing time
5. The attention notes for safe use.

10. Cautions for Use
1. Since the battery is not manufactured for recharging, there are risks of electrolyte leakage or causing damage to the device if the battery is charged.
2. The battery shall be installed with its “+” and “-” polarity in the correct position, otherwise may cause a short circuit.
3. Short-circuiting, heating, disposing of into fire, or disassembling of battery is prohibited.
4. The battery can not be forced to discharge, which s to excess gassing and may result in bulging, leakage, and de-crimping of the cap.
5. New batteries and used ones can not be used at the same time. It is recommended to use the same brand when replacing batteries.
6. Electrical appliances should be taken out the battery when not in use for a long time
7. Exhausted batteries shall be removed from the compartment in order to prevent over-discharge.
8. Prohibit direct welding battery, otherwise, it will damage the battery.
9. Battery is to be kept away from children. If swallowed, contact a physician at once.
 
11. Normal Packing
    Every 2 or 3 and 4 batteries or according to customer requirements with 
transparent membrane after hot shrinkage, each 60 knots in 1 inner box, 
16 boxes into 1 box.
 
12. Storage and shelf life
1. Batteries should be stored in a ventilated, cool, and dry place。
2. The battery should not be exposed to direct sunlight for a long time or in the rain。
3. Not to mix removed packaging battery stack together
4.Stored at condition of tempreture20℃±2℃, relative humidity 60±15%RH, the battery shelf life is 2 years。

13. Typical discharge curve
Discharge environment:20℃±2℃,RH60±15%
With parameter adjustment, product technology updates, and technology specifications will update at any time, please do not hesitate to contact us to stand for the latest version of the specification.

Get Free Quotes


About Us

Changzhou Strengh (Anyida) Power Technology Co., Ltd. is a private enterprise in Jiangsu specializing in the research, development, production and operation of primary batteries. The company's advanced production equipment, sophisticated testing equipment, and standardized management provide a reliable guarantee for the stability and improvement of product quality. A large amount of capital has been invested in new product development and technological innovation, and a large number of high-tech talents have been introduced. At present, engineering and technical personnel have accounted for more than 25% of the total number of employees, with strong economic and technical strength. The company has passed ISO9001, ISO14001, UL, CE, ROHS, SGS, REACH and other certifications and tests.